Settings
The Settings tab allows users to configure and manage various operational, connection, storage, and security parameters for their robot. The settings are categorized into several sections accessible via the left-hand navigation menu.
1. General
The General section covers the basic identification, software version, and local network connection details of the robot.
- Robot name: View and edit the display name of the robot (e.g.,
QA_robot_new). - Robot image: Upload or change the visual avatar representing the robot in the platform.
- Agent: Displays the currently installed version of the robot agent. It indicates if a new version is available and provides an Update Agent button.
- Local connection: Provides the IP address and port required to connect directly to the robot via a local network (e.g.,
https://10.170.2.52:19993). It also includes options to copy the URL, open it in a new tab, and a button to download the Linux desktop app.
You can change the robot name while offline in local mode. For direct access and local editing requirements, see Local Access & Monitoring.
The Agent also exposes a Local API Gateway. Applications can use its Live Stream WebSocket to receive continuous data from supported robot streams or send supported teleoperation commands. This local connection is separate from the Cloud API.
2. Recordings
Set up and manage data capture from the robot. Recordings are automatically uploaded based on the configured storage provider.
- Add Video Recording: Configure video captures to record footage directly from connected camera devices or video streams.
- Add CSV Recording: Configure text-based data persistence to log stream data over time.
For more information on managing and using recordings, see the Recordings documentation.
3. Notifications
Configure alerts triggered when specific system conditions or thresholds are met.
- Notifications quota: Displays a progress bar showing the monthly usage out of the allocated limit for SMS (e.g., 0 of 100), WhatsApp (0 of 100), and Email (0 of 1000) notifications.
- Built-in notifications: Toggle and set percentage thresholds for automatic system alerts:
- CPU threshold: Alerts when CPU usage exceeds the specified percentage.
- RAM threshold: Alerts when RAM usage exceeds the specified percentage.
- Disk usage threshold: Alerts when disk usage exceeds the specified percentage.
- Custom Notifications: An + Add Custom Notification button allows users to define specific operator rules and thresholds for re-notification.
4. Custom KPI
Create and track custom Key Performance Indicators (KPIs) to monitor specialized metrics. These values are displayed in the monitoring pages and robot tables.
KPIs provide periodically updated, stateful data from devices for robot and fleet monitoring. A KPI can expose a selected message field or an aggregate instead of requiring each viewer to work directly with the source stream.
Creating a Custom KPI
- Open the robot's Settings tab and select Custom KPI.
- Click Add.
- Enter a Name of up to 20 characters. Start with an alphanumeric character; subsequent characters can be alphanumeric, dots, underscores, or hyphens. Spaces are not accepted.
- Enter optional Measurement units to identify the value's unit.
- Select the Stream source. Once its message fields load, use Field selection to choose the value to track.
- Choose a Metric: Raw (None), Sum, or Average. For an average, configure the Resolution control to select the aggregation interval.
- Click Add to create the KPI, or Cancel to discard the draft.
For example, name a KPI battery_voltage, use V as its units, select a battery-state stream, and choose its numeric voltage field. The available streams and fields depend on the robot.

The example below uses Average with Hour resolution. These are example choices, not required settings for every KPI.

Using and Managing KPIs
Custom KPI values can be used in Monitoring viewers, robot tables, fleet views, and API streams. For example, in a 3D pose layer, select KPI under Primary Source, then choose the configured KPI source instead of a direct stream.
Existing KPI cards show their stream, units, metric, and resolution. Use Edit KPI to change a definition. Clear historical data and Delete KPI are separate actions; use them only when you intend to remove stored history or the KPI itself.
KPIs can also be configured locally. For local or headless inspection and configuration import/export, see the KPI Manager.
5. Storage
Select the primary storage provider for uploading resources such as video logs and CSV recordings.
- Storage Providers available:
- Cogniteam Cloud
- AWS S3
- Locally on the Robot
Local Resource Quota
Local resource storage supports a configurable limit, with automatic rotation of old local data when the limit is reached. This quota controls resource data on the robot independently of the selected upload provider; it is also available when Cogniteam Cloud is selected.
- Open Settings and select Storage.
- Review Total disk space and Disk space used by resources.
- Enable Limit disk space used by resources.
- Enter a Resources quota and select its Unit.
- Click the quota section's Save button to apply the limit.

The screenshot uses 1 GB as an example, not a recommended quota. Choose a limit that accommodates the deployment's recordings and other resources while leaving sufficient disk space for the robot's other processes. Local rotation can remove older data, so plan retention and uploads accordingly.
Automatic Database-Space Maintenance
The Agent attempts to reclaim eligible unused database space during startup, no more than once every 24 hours. This maintenance is separate from resource quotas and recording retention; it does not replace capacity planning or guarantee that every startup frees space.
AWS S3 Configuration (when selected)
To configure AWS S3 storage, you need to set up your AWS account and obtain the necessary credentials. Follow these steps:
Step 1: Create an S3 Bucket
- Log in to the AWS Management Console.
- Navigate to S3 and click Create bucket.
- Choose a bucket name (e.g.,
automation-test-upload). - Select the appropriate region (e.g.,
eu-north-1). - Create the bucket with default settings or customize as needed.
Step 2: Set Up IAM Policy
To allow secure access to your bucket, create an IAM policy with the necessary permissions:
- Navigate to IAM → Policies → Create Policy.
- Use the following policy document (replace
YOUR_BUCKET_NAMEwith your actual bucket name):
{
"Version": "2012-10-17",
"Statement": [
{
"Effect": "Allow",
"Action": ["s3:PutObject", "s3:GetObject", "s3:DeleteObject"],
"Resource": "arn:aws:s3:::YOUR_BUCKET_NAME/*"
},
{
"Effect": "Allow",
"Action": ["s3:ListBucket"],
"Resource": "arn:aws:s3:::YOUR_BUCKET_NAME"
}
]
}
Step 3: Create Access Keys
- In the AWS Management Console, navigate to IAM → Users.
- Select your test user (or create one if needed).
- Go to the Security credentials tab.
- Click Create access key.
- AWS will provide two values:
- Access Key ID
- Secret Access Key
Store these credentials securely.
Step 4: Configure in Robot Settings
In the Robot Settings tab, enter the following information:
- Access key: Your Access Key ID from AWS
- Secret key: Your Secret Access Key from AWS
- Bucket name: Your S3 bucket name (e.g.,
automation-test-upload) - Region: The region where your bucket is located (e.g.,
eu-north-1)
Once configured, all files uploaded using the upload-file command in the Nimbus CLI reference will be automatically sent to your AWS S3 bucket.
Object Lock-enabled S3 buckets require upload checksums. Nimbus includes checksums for S3 uploads, including large files uploaded in multiple parts.
Important: To avoid sync conflicts and performance issues, we recommend storing files to be uploaded in locations outside of Nimbus synced folders on the robot. Preferably, use a dedicated directory that is not monitored by Nimbus synchronization.
Step 5: Verify the Setup with AWS CLI
You can verify that your AWS credentials and bucket access are configured correctly using the AWS CLI.
First, configure your credentials:
aws configure
Enter the following values:
AWS Access Key ID: <your access key>
AWS Secret Access Key: <your secret key>
Default region name: eu-north-1
Default output format: json
Then upload a test file:
aws s3 cp test.txt s3://automation-test-upload/ --region eu-north-1
If the command succeeds, your AWS S3 storage configuration is working.
6. Docker Registry
Manage authentication credentials for private container registries, which are necessary when pulling custom component images.
- Add private docker registry: Clicking this opens a modal requiring the following details:
- URL: The registry endpoint.
- Username: Authentication username.
- Password: Authentication password.
For endpoint examples, access-token permissions, verification, and public-to-private transitions, see Using private container registries.
7. ROS
Configure the networking parameters specifically for the Robot Operating System (ROS) environment.
- ROS IP: Set the IP address for the ROS node (e.g.,
127.0.0.1). - ROS Master URI: Define the URI for the ROS Master (e.g.,
http://127.0.0.1:11311). - ROS 2 Domain ID: Set the domain ID for ROS 2 communications to isolate traffic on the same network.
8. Security
Enhance the robot's physical and network security by restricting access to external interfaces and communication channels.
- Block HTTP ports: A toggle that blocks unsecured HTTP-like ports using an iptables rule.
- Block USB storage: A toggle that disables USB mass-storage devices (usb-storage / UAS) and applies a udev rule to prevent unauthorized physical data extraction or malware injection.
- Disable Wi-Fi: A toggle that turns off all Wi-Fi radios and interfaces via NetworkManager and wpa_supplicant.
- Disable Bluetooth: A toggle that turns off the Bluetooth radio and stops the corresponding Bluetooth service.
9. Debug
Use Debug settings for advanced diagnostics and support collection.
The interface provides the sections below; available controls depend on the installed Agent and web application versions.
- Open the robot's Settings tab and select Debug.
- Configure only the collection and retention options needed for troubleshooting.
- Use the relevant section's Save button to apply its changes. Separate sections have separate Save controls.
Web App Telemetry
Enable web app telemetry controls diagnostic publishing from the browser to the Agent. Publish interval (seconds) sets the minimum interval between diagnostic publishes.
Enable Limit retained diagnostic storage, then configure Storage limit and Unit to bound the browser diagnostics retained on the Agent.

The screenshot shows telemetry enabled with a 30-second interval and a 64 MB retained-storage limit. These are example values, not universal defaults.
Memory Diagnostics
Use Enable memory diagnostics to control memory diagnostic collection, then save that section.
The screenshot shows collection disabled; inspection of this setting does not require enabling diagnostics.
Agent Logs and Diagnostics Export
The Agent log controls configure the minimum log level and retention limits by age and size. Export controls also limit the log time window and exported size.
Diagnostics export settings bound the default collection window, total ZIP size, and per-domain size. Review these limits before collecting a support bundle, especially when storage is constrained.
Support Collection
Optional CPU and memory diagnostics are available on Linux systems. When enabled, diagnostics collect CPU averages, CPU peaks, and memory history for the local Debug page, with timestamped samples included in support bundles. Collection is disabled by default.
Support reports can highlight CPU peaks, gaps in diagnostic history, and incomplete time coverage. Check that the collected period covers the incident before interpreting an absence of samples as an absence of a problem. Recording analysis also distinguishes recovered recorders from those with ongoing failures.
Support bundles can include diagnostics for:
- Recordings
- WebRTC
- Stream uploads
- Metric uploads
- Installation and upgrades
- Memory-related problems
- CPU peaks and gaps in diagnostic history
Credentials remain redacted from support bundles. For command-line bundle creation and upload, see the Debug Manager.
Support reports distinguish out-of-memory evidence from routine system messages and include thread snapshots. Interpret these reports alongside the incident timeline rather than treating an isolated message as proof of a memory failure. The application sidebar's Support link opens the support page directly.
10. Cloud Video and Stream Monitoring
Robots can disable cloud video and stream monitoring while keeping local monitoring and remote-maintenance capabilities available. Use this option when a deployment should retain local access but avoid sending live video or stream monitoring data to the cloud.